DESCRIPTION
Refer to DTC P27137F.
Click here
DTC No. | Detection Item |
DTC Detection Condition | Trouble Area |
MIL | Memory |
Note |
---|---|---|---|---|---|---|
P271314 |
Pressure Control Solenoid "D" Circuit Short to Ground or Open |
While the engine is running, a short to ground or open is detected in the solenoid (SLT) valve circuit for 1 second (1-trip detection logic). |
| Comes on |
DTC stored | SAE Code: P2720 |
MONITOR DESCRIPTION
When an open or short to ground in the solenoid (SLT) valve circuit is detected, the ECM will determine that there is a malfunction, illuminate the MIL and store this DTC.
MONITOR STRATEGY
Related DTC | P2720: Solenoid (SLT) valve/Range check (Low current) |
Required sensors/components |
Solenoid (SLT) valve |
Frequency of operation |
Continuous |
Duration |
Condition (a): 1 sec. Condition (b): 1.1 sec. |
MIL operation | Immediate |
Sequence of operation | None |
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored |
None |
Solenoid current cut status |
Not cut |
Engine switch |
On (IG) |
Starter |
OFF |
Battery voltage |
10.5 V or more |
Target current (0.1 sec. or more) |
0.2 A or more |
TYPICAL MALFUNCTION THRESHOLDS
Any of the following conditions are met |
(a) or (b) |
(a) Solenoid current |
Less than 0.075 A |
(b) Solenoid high current cutout by solenoid driver IC |
ON |
COMPONENT OPERATING RANGE
Solenoid current | 0.075 A or more |
Solenoid high current cutout by solenoid driver IC |
OFF |
CONFIRMATION DRIVING PATTERN
HINT:
Click here
HINT:
[*1] : Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
Techstream Display |
Description |
---|---|
NORMAL |
|
ABNORMAL |
|
INCOMPLETE |
|
N/A |
|
HINT:
WIRING DIAGRAM
Refer to DTC P271312.
Click here
CAUTION / NOTICE / HINT
NOTICE:
Click here
Click here
PROCEDURE
1. | CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE (SOLENOID (SLT) VALVE) - ECM) |
(a) Disconnect the C96 ECM connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection | Condition |
Specified Condition |
---|---|---|
C96-67 (SLT+) - C96-37 (SLT-) |
20 |